Nader

NDZ3T-200 Series DC Contactor, Nader

Model: NDZ3T-200

Key specifications

  • Rated current In (A) 200A
  • Rated working voltage Ue DC750V
  • Coil control voltage Uc (V) DC12V/24/48V

Technical parameters

Rated current (A)

200A

Rated voltage Ue (V)

DC750V

Main Circuit Polarity

Polarized

Insulation voltage Ui (V)

DC1000V

Control Coil

Rated voltage Ui (V)

DC12V, DC24V, DC48V

Operating Voltage

75%~110% Uc

Drop-out Voltage

10%~60% Uc

Coil Polarity

Polarized

Turn-on Time (20°C, Rated Voltage)

≤30ms

Turn-off Time (20°C)

≤10ms

Coil Power Consumption (20°C)

Pick-up: 35W; Hold: 4.5W

Installation position torque

M5 screw(3~4N.m)

Wiring terminal torque

M6 screw(6~8N.m)

Certificates

CCC, CE, CB, TUV, UL

Mechanical life

200000 times, frequency 3600 times/h

Electrical life (Make 0.6s/Break 5.4s, Resistive Load)

DC750V 200A

1000 times

DC500V 200A

3000 times

DC500V 200A

1000 times

Maximum breaking current

DC750V 2000A

once

Short-circuit withstand current

10Ie 600ms

Contact Resistance (at Rated Current)

≤0.2mΩ

Insulation resistance

1000mΩ, DC1000V

Dielectric Strength

AC3000V 60s

(leakage current ≤1mA)

Shock Resistance

·Stability: 20g (ON state), 10g (OFF state) (half-sine pulse: 11ms, detection time 10μs)

·Destruction: 50g

(half-sine pulse: 6ms)

Vibration Resistance

10~500Hz 5g

Normal Working Environment

·Operating environment:-40~85℃

·Operating humidity:5%~95%

·Pollution level:3

·Protection class:IP67(Except the connecting terminals)

·Installation direction:Vertical installation

Installation Mode

Screw mounting

Environmental Compliance

Comply with the RoHS directives